Guangdong Yuemei teach you to protect the installation of standard knowledge
"Civil design principles" GB 503522005
6.6.3 balcony, corridor, indoor corridors, patio, people on the roof and outdoor stairs airport at should be provided with protective railing, and shall comply with the following provisions:
1 the rail shall be made of a firm and durable material and capable of bearing the level of the load codes;
2 Airport height 24m below, railing height should not less than 1.05M, airport in height over 24m and 24m (including high-rise residential buildings), railing height should not less than 1.10M;
Note: top railing height from the floor or roof to the handrail handrail vertical height calculation, such as the bottom have width is equal or greater than 0.22m and height less than or equal to 0.45M can step position, should be set foot position calculation of top surface.
3 bars from the floor or roof 0.10m height should not be blank;
4 houses, nurseries, kindergartens, schools and special for children activities places of the railing must prevent the use of children climbing structure, when the vertical member of rails, the bar spacing should not be more than 0.11M;
5 culture and entertainment buildings, commercial building services, sports, architecture, landscape architecture, allow children to become active in the place, when the vertical member of rails, the bar spacing should not be more than 0.11M.
The 6.10.3 window should be in accordance with the following provisions:
Open the form 1 sash should be easy to use, safe and easy maintenance and cleaning;
2 when the window sash should strengthen the firm measures;
3 open to the public aisle window, the bottom surface height should not be lower than 2m;
4 airport window is less than 0.80M, should take protective measures, door height from the ground floor of the calculation should not be less than 0.80m;
The 5 firewall must open window, should be set according to the code for fire protection;
6 the skylight shall be used against the transmission and injury of the transparent material;
7 measures for preventing condensation water from generating or discharging condensate water;
8 skylight should be easy to open, close, fixed, waterproof, and easy to clean.
Note: 1 residential sill below 0.90M, should take protective measures;
2 low ledge, lower part and so on the person stand wide window table, window guardrail or the fixed window door height should be from the window surface calculation.
"Civil design principles" GB 503522005 provisions
6.6.3 the two balcony, corridor, airport railing height should be more than the height of the center of gravity of the human body, in order to avoid the body close to the railing for center of gravity shift and fall. According to the relevant units in 1980 to 14, body measurements in China: China’s men’s average height was 1656.03mm, converted into the focus of human upright state of the height is 994mm, the height of center of gravity shoes after 99420 = 1014mm, so in the national standard "fixed rail industry" stipulated: "protective railing shall have a height less than 1050mm, so" the provisions of this article 24m below the airport height (equivalent to low layer, multilayer building height) railing height should not be lower than 1.05M, more than 24m airport height (equivalent to high-rise and high-rise residential height) of the rail height should not be lower than 1.10M, for the high-rise buildings, because of high altitude overlooking there will be fear so, increased to 1.10m. Note that when baluster bottom have width is equal or greater than 0.22m and height less than or equal to 0.45M can step position, by stepping on the normal people, people are very easy to set foot on and stood looking (instead of climbing), at the height of the railing as from the ground floor or roof starting, to pole fence handrail top surface height less than the height of the center of mass of the people, very safe, so it should be set foot position calculation of top surface.
Article 4, paragraph 5 for the safety of the protection of children and their special place railings should prevent climbing are constructed using, such as not to do lateral floriation, parapet wall waterproof material head walk along the small brick. When the vertical railing, the net distance between the members should not be greater than 0.11M, in case the head belt passing through and fall. In recent years, in shopping malls and other buildings, some rail vertical bar between the spacing is about 0.20 m, children falling accident, so children can go places and do single vertical bars and rods spacing should not exceed 0.11M.
This article also referred to the ISO / DIS 12055 "housing construction - the building of the fence system and railings" standard.Catalog printing Booklet printing